Kanal VarnaDrains • Leaks • Thermal imaging • Plumbing
Digital meter showing 24.1 °C and 44 % air humidity

Damp survey in Varna: measuring moisture in walls, floors and screed

Is that wall wet, how far does it go, and is it getting better or worse? We measure moisture in walls, floors, screed and ceilings with two meters and a thermal camera, and write the numbers down on a sketch with photos and a date, so you know whether it is dry and can show it to a tradesman, a neighbour or an insurer.

Our clients on video · all videos (in Bulgarian)

Two metersPin meter and non-contact meter, plus a thermal camera to guide them
Dry spotEvery reading is compared with the same material where it is dry
Sketch and photosPoints, values, photos and the date
Second visitSame points measured again to see if it is drying
1000+ clients served 30+ years in the trade Price agreed before we start 06:00–23:00 every day
In short

A damp survey in Varna is more than one number from a meter. Kanal Varna measures at many points on the wall, floor or ceiling, compares each reading with a dry spot of the same material, and uses a thermal camera to show where to look. You get a moisture map: a sketch with readings, photos and a date, so you can decide when to paint or lay a new floor, or show it to a neighbour or an insurer. We tell you the price before we come. For the causes of damp, start at our mould and damp page. Call +359 52 993 333 or email info@kanalvarna.com — write to us in English and we reply in English.

Updated November 2026

When you need a damp survey

You need one when a decision or an argument depends on how wet something is and how far it extends: after a leak, before painting or laying a new floor, in a dispute with a neighbour or an insurer, or when a floor fitter wants proof that the screed is ready. The answer is a map with numbers, not a judgement by eye.

SituationWhat we measureWhat you get
Leak from the flat above; ceiling and walls are wetThe ceiling and walls: how far the water has spread and whether the zone is growingA moisture map for the insurer or the neighbour
Laminate has swollen after a washing machine or dishwasher leakThe floor around the appliance and along the way the water ranHow far it is wet under the flooring and what has to be opened — see water under the floor
You want to paint or lay a new floor after a leakThe same points as the first time, plus the dry spotAn answer: ready, or wait
A damp corner or a wall with mouldThe corner, the wall around it and the surface temperatureWhether the damp is only on the surface or comes from inside

If you are buying a flat, a damp survey is part of a survey before buying.

Measuring moisture in walls: what each instrument shows

We use three instruments because each sees something different, and none gives the whole picture alone.

  • Pin meter. It measures electrical resistance between two pins: the more water, the easier the current passes. On plaster, concrete and brick the reading is relative — it says wetter or drier than the next point, not a percentage of water. Salts in old walls raise the reading too.
  • Non-contact meter. It slides over the surface and responds to water a few centimetres deep. Nothing is drilled, which suits tiles and painted walls. Metal behind the surface — reinforcement, pipes, plasterboard profiles, foil — raises the reading and can mislead.
  • Thermal camera. It shows surface temperature, not water, and works well only when there is a temperature difference, for example with heating on in the cold season. A wet area is often colder, but a cold patch can also be a thermal bridge or a cold pipe. So we check every suspect place with a meter.
Thermal image of a building from above, with warmer and colder zones in different colours

Why one reading is not enough

A single number from a meter misleads, because without comparison it says nothing. The same value can mean dry on one plaster and wet on another. What matters is the difference between points and between two days.

  • Surface only. Condensation on a cold wall gives a high reading with no water inside. Short pins, on the other hand, measure only the top layer and can miss what is wet underneath.
  • One point. Moisture from a leak is uneven: strong near where the water comes from and falling off to the sides. A single reading can land on a dry patch right next to the wet one.
  • No date. One reading cannot tell you whether the wall is drying or the water is still arriving. A second reading at the same points does.

If you want to check something yourself first, use your own meter carefully and compare with a dry wall of the same material. If the difference does not go away after several days of airing, it is worth a proper survey.

The moisture map: how we measure walls, floors, screed and ceilings

The map is a sketch of the room with numbered points and the value at each. We measure across the affected area and beyond it, until the readings fall to those of the dry spot. That shows the edge of the wet zone — how big it is, which way it spreads and where the water probably comes from. The dry spot is a point of the same material in the same room, away from the affected area, wet rooms and external walls. If there is none, because the whole floor was under water, we compare with another room.

  • Walls. At several heights: water from a leak runs down, rising damp climbs from below, condensation sits in the cold corners. If the readings fall with height, it is probably damp from the foundations — see rising damp.
  • Floors. Tiles are measured without contact and in the grout lines; laminate and parquet along the edges and by the walls. If the screed has to be seen, we say where it is least destructive to open.
  • Screed. At several points across the room, because screed dries unevenly — more slowly where it is thicker or covered.
  • Ceilings. On the stains, around them and towards the walls. With a plasterboard ceiling we remember that metal profiles raise the non-contact reading.
Hands writing and drawing a sketch on a sheet on a clipboard

Tell us what happened, when the water stopped and what you need the result for. We tell you the price before we come.

📞 +359 52 993 333

What the measurement record contains

A record someone else can check: where we measured, with what, what the instrument showed and when. A value without a point on the sketch and a date proves nothing, so all three are there.

  • Date and time of the measurement, and what happened and when the water stopped — in your words.
  • A sketch with numbered points and the dry spot marked.
  • The value at each point and the instrument used.
  • Photos of the areas and thermal images of the same places.
  • A conclusion: how far the moisture reaches, whether it is growing or falling compared with the last measurement, and whether there are signs the water is still arriving.
  • A recommendation on what to open or dry, and when to measure next.

It describes condition and values. Who is responsible and what the damage costs is not for us to decide — that is for the insurer and, in a dispute, for the lawyers. For the insurance side see our leak report for insurance page; for the neighbour question, a leak from the flat above.

Before painting or a new floor

The question to answer is simple: have the readings come down to those of the dry spot? We measure at the same points as the first time and compare. If they are still falling, it is too early — paint on damp plaster blisters and flakes, and a new floor on wet screed seals the water underneath. Once the readings match, the wall is ready for filler and paint — cover the old water stain with a stain-blocking primer first. How to dry the room in the meantime is covered in drying after a leak.

If the floor fitter asks for proof that the screed is dry, note that many flooring makers require a carbide (CM) test — a sample from the screed itself, not a meter reading. Our meters show whether the screed is still drying but do not replace a CM test. Ask the fitter exactly what they need and tell us beforehand. If there are mould stains on the wall, see mould removal: cleaning comes after the survey shows a dry wall.

How the visit goes

  1. A conversation first. What happened, when the water stopped, what the floor and walls are made of, and what you need the result for. Photos from the day of the leak help.
  2. Thermal camera walk-through. We go through the affected and the neighbouring rooms.
  3. Grid measurement. Both meters, at points marked on a sketch, plus the dry spot.
  4. The source, if water is still arriving. We look for where it comes from, with the same instruments, an acoustic device and a pressure test — see leak detection.
  5. Record and a second measurement. The sketch, values, photos and conclusion, then a second measurement at the same points until the values match the dry spot. We tell you the price before we come, and you pay after the work.

If you are not in Bulgaria

Often the owner hears about a wet wall from a guest or a cleaner. You do not have to be there: send us the address, photos of the stain and the name and phone number of the person who can let us in. We tell you what we found and what the numbers mean, and a second measurement can be arranged with the same person. You can pay by bank transfer.

Frequently asked questions

Is a thermal camera enough to see moisture in a wall?

No. It shows surface temperature, not water. A wet place is often colder, but a cold patch can also come from a thermal bridge or a cold pipe. So every suspect place is checked with two meters, a pin meter and a non-contact one that scans a larger area a few centimetres deep without drilling.

My own damp meter shows a high number. Is the wall wet?

Not necessarily. On plaster and concrete the number is relative and depends on the scale and mode of the device, on salts in the wall and on condensation on the surface. Compare it with a dry spot of the same material. If the difference is large and does not go away after a few days of airing, have it checked.

Can you measure moisture in a new flat before renovation?

Yes. In new buildings the plaster and screed still give off building moisture, and some walls may be wet from the roof, the balcony or neighbours. We measure at points on walls and floor, compare them and put them on a sketch. If the floor fitter wants a specific method for the screed, tell us beforehand.

Will you drill the wall or floor?

The non-contact meter and the thermal camera leave no marks. The pin meter leaves tiny holes that are easy to fill, and on tiles we measure in the grout. If the wet is under laminate or behind plasterboard and the base has to be seen, we tell you where it is least destructive to open — the decision is yours.

Can moisture be measured through tiles or laminate?

Yes, with the non-contact meter and without drilling. It responds to water a few centimetres below the surface and gives relative values, so we compare with a dry area of the same floor. Metal, foil and underfloor heating can distort the reading.

Do you measure damp when buying or renting a flat?

Yes. When buying, the measurement is part of the survey described on our survey before buying page. For a rented flat, or just one wall or floor, tell us what to measure when you write.

Need a damp survey?

Tell us what happened, when the water stopped and what you need the result for. We tell you the price before we come.

📞 +359 52 993 333

or email info@kanalvarna.com — write in English and we reply in English.

Send us a message

Leave your name and a phone number with the country code. Add your email if you prefer a written reply — write in English and we reply in English. We confirm the price before any work starts.

📞